Our Calibration Technicians have used Insacal Conductivity Calibrators for years, and have helped select and develop the most useful accessories for both laboratory and field work. 

Additional Calibrations 

Gain a deeper understanding of the linearity of the sensor with a multi-point comparison calibration. This complements the standard calibration of the Insacal® Conductivity Calibrator, 6-point accredited temperature calibration and an accredited electrical calibration of the transmitter. 

Insatech calibration laboratory offers a broad range of accredited calibrations, and the Insacal® Conductivity Calibrator can therefore be calibrated to your needs. 

DFM Ref Væsker 2019 16 9
Accesories Insacal Conductivity Tubes

Tubes 

At very low conductivity measurements, many elements can contribute to higher conductivity. One of these is the tubing used to pass the calibration solution through the flow fitting. Tubes vary in quality and heat transfer, both of which can have a significant influence on the calibration. Therefore, we highly recommend using our tested and verified tubes to ensure you get the best possible calibration. The tubes are supplied with mini-clamps at both ends.

T9 Calibration Tank 

Insacal T9 Calibration Tank for Insacal Conductivity Calibratorss enables efficient loop calibration of your conductivity sensors. Your sensor can be connected directly to the tank together with the Insacal Conductivity meter.

The tank holds up to 9 litres of calibration solution, which is circulated by an integrated pump through both the unit under test and the Insacal Conductivity Calibrator. This ensures a stable flow and makes sensor calibration straightforward and reliable.

Read more about our T9 Calibration Tank

Insacal T9 Calibration Tank
T14 Calibration Tank 16 9

T14 Calibration Tank 

Insacal T14 Calibration Tank for Insacal Conductivity Calibratorss enables efficient loop calibration of your conductivity sensors. Your sensor can be connected directly to the tank together with the Insacal Conductivity Calibrator.

The tank holds a larger volume and higher temperature than our T9 Calibration Tank, allowing for extended calibration setups and increased flexibility. The solution is circulated by an integrated pump through both the unit under test and the Insacal Conductivity Calibrator. This ensures a stable flow and makes sensor calibration straightforward and reliable.

Read more about our T14 Calibration Tank

Fittings

If the standard fittings are not sufficient, we can supply special fittings on request – for example, fittings that allow you to connect long sensors as well as a variety of process connections.

Accesories Insacal Conductivity Fittings
Accesories Insacal Conductivity Storage Case

Transportation and storage case

Keep your Insacal Conductivity safe during transport or storage with a custom-fit Pelican case. The case interior is fitted with custom-tailored foam. The case also has wheels, which makes transporting your Insacal very easy.

DOMO Website
Dorte Krüger Molin

Export Manager


Tel.: +45 2761 4503

Email: Dorte.Molin@insatech.com 

Write to Dorte

Insatech Medarbejdere Website MOSV
Morten Lyhne Svendsen

Product Manager Calibration & Analysis


Tlf: +45 2761 4500

Email: 
Morten.Svendsen@insatech.com

Write to Morten

To top